Canal Winchester Heating & Cooling Rated 5.0 out of 5 stars based on 3 customer reviews

Map of Blacklick, OH

Great Service




Review of Canal Winchester Heating & Cooling

We always have a great experience with Canal Heating & Cooling...between the customer service they provide and technicians always so friendly, we wouldn’t go anywhere else!


Map of Blacklick, OH

Great service




Review of Canal Winchester Heating & Cooling

My furnace went out and I received a same day new furnace installed!


Map of Blacklick, OH

Quick service




Review of Canal Winchester Heating & Cooling


Haidar H.

Haidar H.

118775

Near Ashcraft Ave, Blacklick, OH 43004
Tony C.

Tony C.

During a tune up on a Carrier air conditioner, I found that the blower capacitor is reading low, customer has chosen not to replace at this time. The capacitor is also reading a little low and all other readings are within manufactures specifications at this time.

Near Prairie Willow Dr, Blacklick, OH 43004
Blacklick, OH - During a tune up on a Carrier air conditioner, I found that the blower capacitor is reading low, customer has chosen not to replace at this time. The capacitor is also reading a little low and all other readings are within manufactures specifications at this time.
Cory C.

Cory C.

I provided an estimate for installation of a Five Star 80% 70,000 BTU Gas Furnace and a Five Star 13 SEER 2.5 Ton Air Conditioner. Customer will let us know how they would like to proceed.

Near Preswicke Mill, Blacklick, OH 43004
Blacklick, OH - I provided an estimate for installation of a Five Star 80% 70,000 BTU Gas Furnace and a Five Star 13 SEER 2.5 Ton Air Conditioner. Customer will let us know how they would like to proceed.
Tony C.

Tony C.

During a tune up on a 2006 Bryant gas furnace, I found that both the inducer capacitor and the blower capacitor were bad and need replaced. Customer wants to hold off on replacement and may replace furnace next season. Furnace is running at departure.

Near Hutton St, Blacklick, OH 43004
Blacklick, OH - During a tune up on a 2006 Bryant gas furnace, I found that both the inducer capacitor and the blower capacitor were bad and need replaced. Customer wants to hold off on replacement and may replace furnace next season. Furnace is running at departure.
Shane W.

Shane W.

I installed an Aprilaire 600M humidifier. Everything is working properly at time of departure.

Near Wills Run Ln, Blacklick, OH 43004
Blacklick, OH - I installed an Aprilaire 600M humidifier. Everything is working properly at time of departure.
Cory C.

Cory C.

During a tune up on a Lennox gas furnace, the inducer is noisy on start up and during run cycle. The blower capacitor is reading low and needs replaced soon. Everything is working at time of departure.

Near Wills Run Ln, Blacklick, OH 43004
Blacklick, OH - During a tune up on a Lennox gas furnace, the inducer is noisy on start up and during run cycle. The blower capacitor is reading low and needs replaced soon. Everything is working at time of departure.
Tony C.

Tony C.

During a tune up on a Lennox gas furnace, the inducer is noisy on start up and during run cycle. The blower capacitor is reading low and needs replaced soon. Everything is working at time of departure.

Near Wills Run Ln, Blacklick, OH 43004
Blacklick, OH - During a tune up on a Lennox gas furnace, the inducer is noisy on start up and during run cycle. The blower capacitor is reading low and needs replaced soon. Everything is working at time of departure.
Tony C.

Tony C.

During a tune up on a Lennox furnace, I pulled and cleaned the flame sensor. I found that the humidifier is not working due to the solenoid and water valve are bad. Customer to replace humidifier. Everything else is working within specifications at this time.

Near Wills Run Ln, Blacklick, OH 43004
Blacklick, OH - During a tune up on a Lennox furnace, I pulled and cleaned the flame sensor. I found that the humidifier is not working due to the solenoid and water valve are bad. Customer to replace humidifier. Everything else is working within specifications at this time.
Tony C.

Tony C.

I found that the humidifier is not working due to the solenoid and water valve are bad. Customer to replace humidifier.

Near Wills Run Ln, Blacklick, OH 43004
Blacklick, OH -  I found that the humidifier is not working due to the solenoid and water valve are bad. Customer to replace humidifier.
Cory C.

Cory C.

During a tune up on a Lennox gas unit, the inducer motor was loud on start up and during run cycle. I recommend replacing 80% OEM Inducer Motor. The filter is dirty and needs replaced. Everything is operating at time of departure.

Near Wills Run Ln, Blacklick, OH 43004
Blacklick, OH - During a tune up on a Lennox gas unit, the inducer motor was loud on start up and during run cycle. I recommend replacing 80% OEM Inducer Motor. The filter is dirty and needs replaced. Everything is operating at time of departure.