Local Reviews
for Lancaster, OH

Canal Winchester Heating & Cooling Rated 5.0 out of 5 stars based on 6 customer reviews

Map of Lancaster, OH

Very Friendly!




Review of Canal Winchester Heating & Cooling

Our AC went out and it was 83 in our house, so we were desperate. Our tech showed up on time and was very friendly and knowledgeable. He had our AC fixed within an hour!


Map of Lancaster, OH

Very helpful, Great service !!




Review of Canal Winchester Heating & Cooling

He was here on time !! Very helpful with our questions !! Would highly recommend !!


Map of Lancaster, OH

Cory is THE BEST!!




Review of Canal Winchester Heating & Cooling

After experiencing the aftermath of a water leak, floors ripped out, boxes piled everywhere, deafening fans and dehumidifiers running, Cory was the only technician that bothered to put on booties before walking into our house. Cory was knowledgeable and informative. All of our concerns about possible water damage to the furnace were addressed. Any questions were answered. I was impressed with my overall interaction with Canal Winchester Heating and Cooling. They answered the phone when I called, many did not, or did not return my call when I left a message. They were accommodating, came on a Saturday, called to advise they were on the way. 5 Stars I highly recommend!


Map of Lancaster, OH

Great Service




Review of Canal Winchester Heating & Cooling

Very nice employees


Map of Lancaster, OH

shows caring attitude and freindly




Review of Canal Winchester Heating & Cooling


Map of Lancaster, OH

Fast Service




Review of Canal Winchester Heating & Cooling

got next morning service. prompt and fixed problem.


Devin F.

Devin F.

Whole house duct cleaning with Lennox furnace tuneup. All checks are good at this time.

Near Royalton Rd SW, Lancaster, OH 43130
Lancaster, OH - Whole house duct cleaning with Lennox furnace tuneup. All checks are good at this time.
Scott G.

Scott G.

Upon arrival I found a Trane unit not working. LED code giving normal operation alert. Had to jump in to heating mode by connecting R to W. After a few minutes of running, breaker tripped. Reset breaker and furnace, able to get it to run again. Checked and had 27 volts at R and common, and 28 from R to W. After a few seconds though, the voltage on W to R dropped to 13 volts and from R to C it dropped to 8 volts. The blower motor was also showing signs of struggling to work. Combustion test showed 13 ppm, 2.5 C02% and 15 O2% . I suggests replacing board to to voltage inaccuracies, but is concerned that blower motor would also need replaced. Due to age of system, 1993, I do not recommend replacing parts. Customer wants to go with new furnace.

Near S Maple St, Lancaster, OH 43130
Lancaster, OH - Upon arrival I  found a Trane unit not working. LED code giving normal operation alert. Had to jump in to heating mode by connecting R to W. After a few minutes of running, breaker tripped. Reset breaker and furnace, able to get it to run again. Checked and had 27 volts at R and common, and 28 from R to W. After a few seconds though, the voltage on W to R dropped to 13 volts and from R to C it dropped to 8 volts. The blower motor was also showing signs of struggling to work. Combustion test showed 13 ppm, 2.5 C02% and 15 O2% . I suggests replacing board to to voltage inaccuracies, but is concerned that blower motor would also need replaced. Due to age of system, 1993, I do not recommend replacing parts. Customer wants to go with new furnace.
Scott G.

Scott G.

Performed Our Special Tune-Up & Safety Checkout On Trane Gas Furnace To Keep Furnace Running Efficiently For The Winter Season

Near Tecumseh Dr, Lancaster, OH 43130
Lancaster, OH - Performed Our Special Tune-Up & Safety Checkout On Trane  Gas Furnace To Keep Furnace Running Efficiently For The Winter Season
Scott G.

Scott G.

Diagnostic Performed Recommended Replacing High Limit Switch & Pull & Clean Blower Assembly On Trane Gas Furnace To Keep Furnace Running Efficiently For The Winter Season

Near W Glenhurst Dr, Lancaster, OH 43130
Lancaster, OH - Diagnostic Performed Recommended Replacing High Limit Switch & Pull & Clean Blower Assembly On Trane Gas Furnace To Keep Furnace Running Efficiently For The Winter Season
Christopher M.

Christopher M.

Diagnostic Service Call on 2008 Trane Gas Furnace, Tech replaced ignitor.

Near Lancaster, OH 43130
Lancaster, OH - Diagnostic Service Call on 2008 Trane Gas Furnace, Tech replaced ignitor.
Scott G.

Scott G.

Diagnostic Performed Replaced Thermostat Honeywell T1 On Lennox Gas Furnace To Keep Furnace Running Efficiently For The Winter Season

Near Lavender St, Lancaster, OH 43130
Lancaster, OH - Diagnostic Performed Replaced Thermostat Honeywell T1 On Lennox Gas Furnace To Keep Furnace Running Efficiently For The Winter Season
Scott G.

Scott G.

Performed Our Special Tune-Up & Safety Checkout On Rheem Gas Furnace To Keep Furnace Running Efficiently For The Winter Season

Near N Eastwood Ave, Lancaster, OH 43130
Lancaster, OH - Performed Our Special Tune-Up & Safety Checkout On Rheem Gas Furnace To Keep Furnace Running Efficiently For The Winter Season
Scott G.

Scott G.

Diagnostic Performed Installed New Pro 8000 Red Link T-Stat To Carrier Gas Furnace To Keep Furnace Running At Highest Performance For The Winter Season

Near Independence Blvd, Lancaster, OH 43130
Lancaster, OH - Diagnostic Performed Installed New Pro 8000 Red Link T-Stat To Carrier Gas Furnace To Keep Furnace Running  At Highest Performance For The  Winter Season
Scott G.

Scott G.

Diagnostic Performed Replaced OEM 90% AFUE Furnace Inducer Motor On Aireflow Gas Furnace To Keep Furnace Running At Highest Performance For The Winter Season

Near Meadow Ridge Dr, Lancaster, OH 43130
Scott G.

Scott G.

Furnace not working upon arrival. Found ignitor broken. At customer request, replaced. Burners, at times, have incomplete burn across. Two will light, then the other two. Customer knows of situation, willing to ride it out.

Near W 6th Ave, Lancaster, OH 43130