Local Reviews
for Etna, OH


Tony C.

Tony C.

I completed a diagnostic on a Carrier Air Conditioner. I determined that the wiring needed fixed going from the furnace to the condenser for the ac to be able to run. Charged system and fixed the wiring issue. System was operational at time of departure.

Near Mechanic St, Etna, OH 43018
Cory C.

Cory C.

I found that the 2008 Tempstar furnace is getting voltage in the proper places but the inducer motor is locked up. Furnace also has a lot of rust in the cabinet. Customer has opted to replace the inducer motor at this time.

Near Longwood Crossing Blvd, Etna, OH 43062
Tony C.

Tony C.

Upon arrival customer stated the furnace only comes on and runs a couple times a day and does not keep the house warm. We as a company recently came out and found the pressure switch was tripped due to a dirty drain trap. Everything was running at departure. Today, found the same code, pressure switch failed to open or respond. Checked vacuum at switch, switch closes at 1.40”wc, vacuum at switch is 1.53”wc before the system ignites. Ran a combustion test on the furnace and checked the gas pressures, found the CO in the flue reached 1000 ppm before the pressure switch tripped. Adjusted gas pressures from 3.8 to 3.3, CO is now 900 ppm before the pressure switch trips. Checked the exhaust pipes, both pipes are free of debris, noticed both are bellow the snow level but they are not blocked at this time.

Near Pike St, Etna, OH 43018
Etna, OH - Upon arrival customer stated the furnace only comes on and runs a couple times a day and does not keep the house warm.

We as a company recently came out and found the pressure switch was tripped due to a dirty drain trap. Everything was running at departure.

Today, found the same code, pressure switch failed to open or respond. Checked vacuum at switch, switch closes at 1.40”wc, vacuum at switch is 1.53”wc before the system ignites.

Ran a combustion test on the furnace and checked the gas pressures, found the CO in the flue reached 1000 ppm before the pressure switch tripped.

Adjusted gas pressures from 3.8 to 3.3, CO is now 900 ppm before the pressure switch trips.

Checked the exhaust pipes, both pipes are free of debris, noticed both are bellow the snow level but they are not blocked at this time.
Cory C.

Cory C.

Customer stated furnace would blow air but not warm. Found furnace locked out on code 3. Pressure switch failure to close. Found trap clog causing water to back up in inducer and not allow for proper vacuum. Cleared trap and cycled system multiple times. Furnace running properly

Near Pike St SW, Etna, OH 43018
Cory C.

Cory C.

I am Performing our Five Star Tune-Up & Safety Check on a 2018 Bryant Gas Furnace. All readings were within manufacturer's specifications, unit operating properly at this time.

Near Trail E, Etna, OH 43062
Etna, OH - 	I am Performing our Five Star Tune-Up & Safety Check on a  2018 Bryant Gas Furnace. All readings were within manufacturer's specifications, unit operating properly at this time.
Scott G.

Scott G.

Tuneup on Carrier AC. The system is in good working order at this time.

Near Halcyon Dr, Etna, OH 43062
Etna, OH - Tuneup on Carrier AC. The system is in good working order at this time.
Scott G.

Scott G.

Tuneup on Carrier AC. The system is working properly at this time.

Near Pike St SW, Etna, OH 43062
Scott G.

Scott G.

Performed Our Special Tune-Up & Safety Checkout On Bryant Gas Furnace To Keep Furnace Running Efficiently For The Fall/Winter Season

Near Trail E, Etna, OH 43062
Etna, OH - Performed Our Special Tune-Up & Safety Checkout On Bryant  Gas Furnace To Keep Furnace Running Efficiently For The Fall/Winter Season
Greg N.

Greg N.

Pre season tune up/check out on a Carrier brand furnace. heat check on 2003 Bryant 80%. Checked all amp draws, ohms on igniter and combustion analysis. All were ok.

Near Etna, OH 43147
Etna, OH - Pre season tune up/check out on a Carrier brand furnace. heat check on 2003 Bryant 80%. Checked all amp draws, ohms on igniter and combustion analysis. All were ok.
Scott G.

Scott G.

Diagnostic Performed Repaired Broken Condensation Leak On Carier Gas Furnace To Keep Furnace Running Efficiently For The Winter Season

Near Brandy Mill Dr, Etna, OH 43062
Etna, OH - Diagnostic Performed Repaired Broken Condensation Leak On Carier Gas Furnace To Keep Furnace Running Efficiently For The Winter Season